During a mobile C-arm fluoroscopy procedure, an air kerma rate of 3.6 mGy/min is measured at a distance of 2 feet from the radiation source. If a technologist steps back to 6 feet from the source with all other exposure factors unchanged, what is the new air kerma rate?

  1. 1.20 mGy/min, because tripling the distance reduces beam intensity proportionally by a factor of three.
  2. 0.40 mGy/min, because tripling the distance reduces beam intensity to one-ninth of its original value.
  3. 0.90 mGy/min, because moving farther from the C-arm reduces scatter intensity by a standard factor of four.
  4. 1.80 mGy/min, because stepping back to 6 feet halves the radiation intensity across the diverging beam.
Show the answer

B. 0.40 mGy/min, because tripling the distance reduces beam intensity to one-ninth of its original value.

By the Inverse Square Law, I1 / I2 = (D2 / D1)^2, so I2 = I1 × (D1 / D2)^2. Substituting I1 = 3.6 mGy/min, D1 = 2 ft, and D2 = 6 ft yields I2 = 3.6 × (2 / 6)^2 = 3.6 × (1 / 9) = 0.40 mGy/min. Under ARRT radiation physics and OR fluoroscopy safety principles, tripling distance cuts exposure intensity to one-ninth.

Reference: ARRT Radiography Physics — Inverse Square Law (Bushong Ch. 4)

An arterial blood gas drawn on room air from a patient with an acute COPD exacerbation shows pH 7.31, PaCO2 62 mmHg, HCO3- 30 mEq/L, and PaO2 58 mmHg. How should this acid-base disorder be classified?

  1. Uncompensated respiratory acidosis, because the elevated PaCO2 alone drives the low pH without any renal response.
  2. Fully compensated respiratory acidosis, because renal bicarbonate retention has already restored arterial pH to normal.
  3. Partially compensated respiratory acidosis with hypoxemia.
  4. Partially compensated metabolic alkalosis, because bicarbonate exceeds 26 mEq/L while carbon dioxide rises to compensate.
Show the answer

C. Partially compensated respiratory acidosis with hypoxemia.

Normal arterial values are pH 7.35–7.45, PaCO2 35–45 mmHg, and HCO3- 22–26 mEq/L. A pH of 7.31 indicates unnormalized acidemia driven by elevated PaCO2 (62 mmHg, primary respiratory acidosis), while HCO3- is elevated to 30 mEq/L, demonstrating active but incomplete renal compensation (Henderson-Hasselbalch: 6.1 + log10[30 / (0.03 × 62)] = 7.31). PaO2 of 58 mmHg confirms hypoxemia.

Reference: NBRC TMC/RRT Detailed Content Outline — ABG Interpretation (Egan's Ch. 14)

An AP lumbar spine radiograph acquired at 80 kVp and 40 mAs demonstrates adequate image receptor exposure, but the radiographer wants to increase beam penetration and reduce patient skin dose while maintaining equivalent receptor exposure. Applying the 15% kVp rule, which new technical factors should be selected?

  1. 92 kVp and 20 mAs
  2. 92 kVp and 80 mAs to compensate for lower scatter absorption
  3. 68 kVp and 20 mAs to keep receptor exposure unchanged
  4. 95 kVp and 20 mAs by adding 15 kVp and halving mAs
Show the answer

A. 92 kVp and 20 mAs

Under the ARRT 15% kVp rule, increasing kVp by 15% approximately doubles exposure to the image receptor; to maintain constant receptor exposure, mAs must be halved. Here, 80 kVp × 1.15 = 92 kVp (an increase of 12 kVp, not a flat 15 kVp), and 40 mAs / 2 = 20 mAs. Raising kVp while halving mAs also lowers patient entrance skin exposure.

Reference: ARRT Image Production — 15% kVp Rule (Carlton & Adler Ch. 16)

A 5-foot-10-inch (70-inch) male weighing 110 kg actual body weight is intubated for severe ARDS (PaO2/FiO2 = 88 mmHg). Using the ARDSNet lung-protective protocol (male IBW = 50 + 2.3 × [height in inches − 60]), what initial tidal volume (VT) and plateau pressure (Pplat) goal should the respiratory therapist target?

  1. 660 mL (6 mL/kg actual body weight) with plateau pressure maintained at or below 30 cmH2O
  2. 730 mL (10 mL/kg predicted body weight) with plateau pressure maintained at or below 35 cmH2O
  3. 438 mL (6 mL/kg predicted body weight) with plateau pressure maintained at or below 45 cmH2O
  4. 438 mL (6 mL/kg predicted body weight) with plateau pressure maintained at or below 30 cmH2O
Show the answer

D. 438 mL (6 mL/kg predicted body weight) with plateau pressure maintained at or below 30 cmH2O

ARDSNet lung-protective ventilation bases tidal volume strictly on predicted/ideal body weight (PBW/IBW), never actual weight. For a 70-inch male, IBW = 50 + 2.3 × (70 − 60) = 73 kg, so 6 mL/kg IBW = 438 mL (approximately 440 mL). Plateau pressure (Pplat) must be kept <= 30 cmH2O to prevent alveolar overdistension and ventilator-induced lung injury (volutrauma/barotrauma).

Reference: ARDSNet Mechanical Ventilation Protocol; NBRC TMC/RRT — Ventilator Management

A pediatric chest radiograph requires 12 mAs and is initially programmed at 300 mA and 0.04 s (40 ms). To reduce voluntary motion blur in an agitated patient while preserving total mAs via the reciprocity law, the radiographer increases the tube current to 600 mA. What new exposure time is required?

  1. 0.08 s (80 ms), doubling time along with the higher tube current
  2. 0.01 s (10 ms), quartering exposure time to offset higher heat units
  3. 0.02 s (20 ms), halving exposure time to maintain 12 mAs
  4. 0.20 s (200 ms), dividing 12 mAs by 60 mA across the filament
Show the answer

C. 0.02 s (20 ms), halving exposure time to maintain 12 mAs

By the ARRT mAs reciprocity law (mAs = mA × seconds), any combination of tube current (mA) and exposure time (s) yielding the same product produces equivalent receptor exposure. Doubling mA from 300 mA to 600 mA requires halving exposure time from 0.04 s to 0.02 s (600 mA × 0.02 s = 12 mAs), minimizing motion unsharpness.

Reference: ARRT Image Production — mAs Reciprocity Law

Exams this helps with

ExamAgency / IssuerRegion
ARRT Radiography Certification Exam (RT(R))ARRTUnited States
NBSTSA Certified Surgical Technologist (CST) ExamNBSTSAUnited States
ARDMS Sonography Principles & Instrumentation (SPI)ARDMSUnited States
NBRC Therapist Multiple-Choice (TMC & RRT) ExamNBRCUnited States
ASCP Medical Laboratory Scientist (MLS / MLT) BoardASCP BOCUnited States