10 realistic exam questions, graded as you go, with the exact rule or statute citation for every answer. Start free, no sign-up.
Timed mock exam
11 questions in 13 minutes, drawn from every topic. No answers shown until the end, then a full score breakdown, your weakest topics and a review of what you missed.
Prices are in US dollars, plus tax where it applies. Stripe, our payment processor, calculates tax at checkout.
All sales are final. If something is really wrong, such as a duplicate charge or a purchase that does not unlock what you bought, write to support@careerexampro.com and we will put it right.
One-time payment. Nothing renews.
You have an exam ticket for this practice test. Start the timed mock exam to use it.
Exact question counts, passing scores, and allowed reference materials vary by testing window and state/agency. Always confirm current rules with the official testing provider.
Sample questions
During a mobile C-arm fluoroscopy procedure, an air kerma rate of 3.6 mGy/min is measured at a distance of 2 feet from the radiation source. If a technologist steps back to 6 feet from the source with all other exposure factors unchanged, what is the new air kerma rate?
1.20 mGy/min, because tripling the distance reduces beam intensity proportionally by a factor of three.
0.40 mGy/min, because tripling the distance reduces beam intensity to one-ninth of its original value.
0.90 mGy/min, because moving farther from the C-arm reduces scatter intensity by a standard factor of four.
1.80 mGy/min, because stepping back to 6 feet halves the radiation intensity across the diverging beam.
Show the answer
B. 0.40 mGy/min, because tripling the distance reduces beam intensity to one-ninth of its original value.
By the Inverse Square Law, I1 / I2 = (D2 / D1)^2, so I2 = I1 × (D1 / D2)^2. Substituting I1 = 3.6 mGy/min, D1 = 2 ft, and D2 = 6 ft yields I2 = 3.6 × (2 / 6)^2 = 3.6 × (1 / 9) = 0.40 mGy/min. Under ARRT radiation physics and OR fluoroscopy safety principles, tripling distance cuts exposure intensity to one-ninth.
A patient with chronic hypercapnic COPD (baseline PaCO2 56 mmHg) presents in acute exacerbation with tachypnea (RR 28/min) and SpO2 84%. Why is a 28% air-entrainment (Venturi) mask preferred over a non-rebreathing mask (NRM) or standard nasal cannula for controlled oxygen therapy?
It is a low-flow reservoir system that delivers 90%–100% FiO2 while actively venting exhaled carbon dioxide.
It applies continuous positive end-expiratory pressure of 5–10 cmH2O to maintain SpO2 above 99%.
It is a high-flow, fixed-performance device delivering a precise FiO2 independent of breathing pattern.
It traps exhaled carbon dioxide inside a sealed reservoir bag to stimulate central medullary chemoreceptors.
Show the answer
C. It is a high-flow, fixed-performance device delivering a precise FiO2 independent of breathing pattern.
An air-entrainment (Venturi) mask is a high-flow, fixed-performance oxygen delivery device whose total gas output exceeds the patient's peak inspiratory flow, delivering a precise, stable FiO2 (e.g., 24%–50%) regardless of rapid or irregular breathing. In chronic hypercapnic COPD (target SpO2 88%–92%), controlled FiO2 prevents worsening hypercapnia caused by excess oxygen reversing hypoxic pulmonary vasoconstriction, the Haldane effect, and hypoxic drive blunting.
An AP lumbar spine radiograph acquired at 80 kVp and 40 mAs demonstrates adequate image receptor exposure, but the radiographer wants to increase beam penetration and reduce patient skin dose while maintaining equivalent receptor exposure. Applying the 15% kVp rule, which new technical factors should be selected?
92 kVp and 20 mAs
92 kVp and 80 mAs to compensate for lower scatter absorption
68 kVp and 20 mAs to keep receptor exposure unchanged
95 kVp and 20 mAs by adding 15 kVp and halving mAs
Show the answer
A. 92 kVp and 20 mAs
Under the ARRT 15% kVp rule, increasing kVp by 15% approximately doubles exposure to the image receptor; to maintain constant receptor exposure, mAs must be halved. Here, 80 kVp × 1.15 = 92 kVp (an increase of 12 kVp, not a flat 15 kVp), and 40 mAs / 2 = 20 mAs. Raising kVp while halving mAs also lowers patient entrance skin exposure.