10 realistic exam questions, graded as you go, with the exact rule or statute citation for every answer. Start free, no sign-up.
Timed mock exam
10 questions in 12 minutes, drawn from every topic. No answers shown until the end, then a full score breakdown, your weakest topics and a review of what you missed.
Prices are in US dollars, plus tax where it applies. Stripe, our payment processor, calculates tax at checkout.
All sales are final. If something is really wrong, such as a duplicate charge or a purchase that does not unlock what you bought, write to support@careerexampro.com and we will put it right.
One-time payment. Nothing renews.
You have an exam ticket for this practice test. Start the timed mock exam to use it.
Exact question counts, passing scores, and allowed reference materials vary by testing window and state/agency. Always confirm current rules with the official testing provider.
Sample questions
Under NCRP Report No. 116 recommendations and the ALARA principle, what is the annual occupational effective dose limit for an adult radiologic technologist, and which three cardinal actions minimize personnel exposure during interventional procedures?
1 mSv per year, achieved by increasing exposure time, standing close to the collimator, and using filtration
5 mSv per year, achieved by decreasing SID, standing near the patient side of the table, and removing lead drapes
150 mSv per year, achieved by increasing kVp alone while relying solely on personal dosimetry badges for protection
50 mSv per year, achieved by minimizing time, maximizing distance, and using appropriate shielding
Show the answer
D. 50 mSv per year, achieved by minimizing time, maximizing distance, and using appropriate shielding
NCRP Report No. 116 sets the annual occupational whole-body effective dose limit at 50 mSv (5 rem) per year (1 mSv is the annual public limit, 5 mSv is the total gestational limit for an embryo/fetus, and 150 mSv is the lens of the eye equivalent limit). Under the ALARA principle (As Low As Reasonably Achievable), minimizing exposure time, maximizing distance, and using proper shielding are the cardinal protective measures.
Diagnostic ultrasound systems calculate reflector depth using an assumed average propagation speed in soft tissue. What is this standard assumed speed, and what determines the actual propagation speed of sound through a biological medium?
1,540 m/s, determined primarily by the transducer's operating frequency and acoustic output power
330 m/s, determined solely by the medium's stiffness (bulk modulus) and density
1,540 m/s, determined solely by the medium's stiffness and density
4,080 m/s, determined by the system's pulse repetition frequency and pulse duration
Show the answer
C. 1,540 m/s, determined solely by the medium's stiffness and density
Ultrasound scanners assume an average propagation speed of 1,540 m/s (1.54 mm/μs) in soft tissue (330 m/s is air and 4,080 m/s is bone). Under ARDMS SPI physical principles, propagation speed is determined exclusively by the medium—specifically stiffness (directly related, dominant effect) and density (inversely related)—and cannot be altered by the sonographer or transducer settings.
A sonographer scans a patient's liver using a 5 MHz curvilinear transducer, assuming standard soft tissue propagation speed of 1,540 m/s. Using the wave equation c = f × λ, what is the wavelength (λ) of the ultrasound beam in soft tissue?
0.308 mm
0.770 mm, calculated by dividing soft tissue speed by 2 MHz
3.25 mm, calculated by dividing transducer frequency by propagation speed
7.70 mm, calculated by multiplying propagation speed by frequency
Show the answer
A. 0.308 mm
From c = f × λ, wavelength equals propagation speed divided by frequency (λ = c / f). In soft tissue (1.54 mm/μs), λ (mm) = 1.54 / f (MHz). Substituting f = 5 MHz yields λ = 1.54 / 5 = 0.308 mm (or 1,540 m/s ÷ 5 × 10^6 Hz = 3.08 × 10^-4 m = 0.308 mm). Higher frequency produces shorter wavelengths, which improves axial resolution.