Radiography, Sonography Physics & Surgical Tech practice drill
10 realistic exam questions, graded as you go, with the exact rule or statute citation for every answer. Start free, no sign-up.
Sample questions
During a mobile C-arm fluoroscopy procedure, an air kerma rate of 3.6 mGy/min is measured at a distance of 2 feet from the radiation source. If a technologist steps back to 6 feet from the source with all other exposure factors unchanged, what is the new air kerma rate?
1.20 mGy/min, because tripling the distance reduces beam intensity proportionally by a factor of three.
0.40 mGy/min, because tripling the distance reduces beam intensity to one-ninth of its original value.
0.90 mGy/min, because moving farther from the C-arm reduces scatter intensity by a standard factor of four.
1.80 mGy/min, because stepping back to 6 feet halves the radiation intensity across the diverging beam.
Show the answer
B. 0.40 mGy/min, because tripling the distance reduces beam intensity to one-ninth of its original value.
By the Inverse Square Law, I1 / I2 = (D2 / D1)^2, so I2 = I1 × (D1 / D2)^2. Substituting I1 = 3.6 mGy/min, D1 = 2 ft, and D2 = 6 ft yields I2 = 3.6 × (2 / 6)^2 = 3.6 × (1 / 9) = 0.40 mGy/min. Under ARRT radiation physics and OR fluoroscopy safety principles, tripling distance cuts exposure intensity to one-ninth.
An AP lumbar spine radiograph acquired at 80 kVp and 40 mAs demonstrates adequate image receptor exposure, but the radiographer wants to increase beam penetration and reduce patient skin dose while maintaining equivalent receptor exposure. Applying the 15% kVp rule, which new technical factors should be selected?
92 kVp and 20 mAs
92 kVp and 80 mAs to compensate for lower scatter absorption
68 kVp and 20 mAs to keep receptor exposure unchanged
95 kVp and 20 mAs by adding 15 kVp and halving mAs
Show the answer
A. 92 kVp and 20 mAs
Under the ARRT 15% kVp rule, increasing kVp by 15% approximately doubles exposure to the image receptor; to maintain constant receptor exposure, mAs must be halved. Here, 80 kVp × 1.15 = 92 kVp (an increase of 12 kVp, not a flat 15 kVp), and 40 mAs / 2 = 20 mAs. Raising kVp while halving mAs also lowers patient entrance skin exposure.
A pediatric chest radiograph requires 12 mAs and is initially programmed at 300 mA and 0.04 s (40 ms). To reduce voluntary motion blur in an agitated patient while preserving total mAs via the reciprocity law, the radiographer increases the tube current to 600 mA. What new exposure time is required?
0.08 s (80 ms), doubling time along with the higher tube current
0.01 s (10 ms), quartering exposure time to offset higher heat units
0.02 s (20 ms), halving exposure time to maintain 12 mAs
0.20 s (200 ms), dividing 12 mAs by 60 mA across the filament
Show the answer
C. 0.02 s (20 ms), halving exposure time to maintain 12 mAs
By the ARRT mAs reciprocity law (mAs = mA × seconds), any combination of tube current (mA) and exposure time (s) yielding the same product produces equivalent receptor exposure. Doubling mA from 300 mA to 600 mA requires halving exposure time from 0.04 s to 0.02 s (600 mA × 0.02 s = 12 mAs), minimizing motion unsharpness.
Reference: ARRT Image Production — mAs Reciprocity Law