CareerExamPro

NBSTSA Certified Surgical Technologist (CST) Exam practice test

11 practice questions for this exam, each with a full explanation and cited rule or blueprint reference.

Start practising

ARRT, CST, SPI, RRT & ASCP MLS: practice drill

10 realistic exam questions, graded as you go, with the exact rule or statute citation for every answer. Start free, no sign-up.

Timed mock exam

11 questions in 13 minutes, drawn from every topic. No answers shown until the end, then a full score breakdown, your weakest topics and a review of what you missed.

Practice tests that prepare you for this exam

Practise by topic

About this exam

Agency / Issuer
NBSTSA
Region
United States

Exact question counts, passing scores, and allowed reference materials vary by testing window and state/agency. Always confirm current rules with the official testing provider.

Sample questions

During a mobile C-arm fluoroscopy procedure, an air kerma rate of 3.6 mGy/min is measured at a distance of 2 feet from the radiation source. If a technologist steps back to 6 feet from the source with all other exposure factors unchanged, what is the new air kerma rate?

  1. 1.20 mGy/min, because tripling the distance reduces beam intensity proportionally by a factor of three.
  2. 0.40 mGy/min, because tripling the distance reduces beam intensity to one-ninth of its original value.
  3. 0.90 mGy/min, because moving farther from the C-arm reduces scatter intensity by a standard factor of four.
  4. 1.80 mGy/min, because stepping back to 6 feet halves the radiation intensity across the diverging beam.
Show the answer

B. 0.40 mGy/min, because tripling the distance reduces beam intensity to one-ninth of its original value.

By the Inverse Square Law, I1 / I2 = (D2 / D1)^2, so I2 = I1 × (D1 / D2)^2. Substituting I1 = 3.6 mGy/min, D1 = 2 ft, and D2 = 6 ft yields I2 = 3.6 × (2 / 6)^2 = 3.6 × (1 / 9) = 0.40 mGy/min. Under ARRT radiation physics and OR fluoroscopy safety principles, tripling distance cuts exposure intensity to one-ninth.

Reference: ARRT Radiography Physics — Inverse Square Law (Bushong Ch. 4)

A trauma patient of unknown blood type arrives in the operating room in hemorrhagic shock requiring immediate uncrossmatched transfusion of both red blood cells (RBCs) and thawed plasma before ABO/Rh typing finishes. Which emergency blood product pair is universally compatible?

  1. Group AB Rh-positive red blood cells and Group O Rh-negative plasma to prevent anti-D formation
  2. Group O Rh-negative red blood cells and Group AB plasma
  3. Group O Rh-positive red blood cells for all trauma patients regardless of sex and Group O plasma
  4. Group AB Rh-negative red blood cells lacking all A/B antigens and Group A plasma lacking isoagglutinins
Show the answer

B. Group O Rh-negative red blood cells and Group AB plasma

Per AABB Standards and ASCP Immunohematology principles, Group O Rh-negative (O−) RBCs are the universal emergency red cell donor because their membranes lack A, B, and D antigens, preventing destruction by recipient anti-A, anti-B, or anti-D. Group AB plasma is the universal plasma donor because it contains neither anti-A nor anti-B antibodies, making it compatible with recipients of any ABO group.

Reference: AABB Technical Manual; ASCP MLS Immunohematology — Emergency Transfusion

Under NCRP Report No. 116 recommendations and the ALARA principle, what is the annual occupational effective dose limit for an adult radiologic technologist, and which three cardinal actions minimize personnel exposure during interventional procedures?

  1. 1 mSv per year, achieved by increasing exposure time, standing close to the collimator, and using filtration
  2. 5 mSv per year, achieved by decreasing SID, standing near the patient side of the table, and removing lead drapes
  3. 150 mSv per year, achieved by increasing kVp alone while relying solely on personal dosimetry badges for protection
  4. 50 mSv per year, achieved by minimizing time, maximizing distance, and using appropriate shielding
Show the answer

D. 50 mSv per year, achieved by minimizing time, maximizing distance, and using appropriate shielding

NCRP Report No. 116 sets the annual occupational whole-body effective dose limit at 50 mSv (5 rem) per year (1 mSv is the annual public limit, 5 mSv is the total gestational limit for an embryo/fetus, and 150 mSv is the lens of the eye equivalent limit). Under the ALARA principle (As Low As Reasonably Achievable), minimizing exposure time, maximizing distance, and using proper shielding are the cardinal protective measures.

Reference: NCRP Report No. 116; ARRT & ARDMS Clinical Safety — ALARA

Taking this exam soon?

Tell us which exam domains or calculation drills you want more practice on.

Other Hospital Allied-Health Boards exams